DWHG series sunt solenoid gubernator operata FUSUS type valvulae. Haec series initium , finis et directiones fluere solent regere .
Magnitudo | 10 | 16 | 22 | 25 | 32 |
Max operating pressura PAB (MPa) | 31.5 | 35 | 31.5 | 35 | 35 |
Externe exhausit T Portus (MPa) | 31.5 | 25 | 25 | 25 | 25 |
Interne exhausit T Portus (MPa) | (AC) -10 | (AC) -10 | (AC) -10 | (AC) -10 | (AC) -10 |
(DC)-16 | (DC)-16 | (DC)-16 | (DC)-16 | (DC)-16 | |
Externe exhausit Y Portus (MPa) | (AC) -10 | (AC) -10 | (AC) -10 | (AC) -10 | (AC) -10 |
(DC)-16 | (DC)-16 | (DC)-16 | (DC)-16 | (DC)-16 | |
Min. Gubernator pressura (MPa) | 0.45-1 | 0.45-1.3 | 0.45-1 | 0.45-1 | 0.45-1 |
Maximilianus. influunt rate (L/min) | 160 | 300 | 450 | 650 | 1100 |
Pondus (KGS) | 6.7 | 9.5 | 12 | 18 | 38.5 |
Valvae corpus(Material)Superficies treatment | phosphating superficiem mittentes | ||||
Oleum munditiae | NAS1638 class 9 and ISO4406 class 20/18/15 |
Curvarum propriae Typus 4DWHG10…(Mensus cum HLP46,Voil=40℃±5℃)
HLP46,Voil = 40℃±5℃) .
HLP46,Voil = 40℃±5℃) .
HLP46,Voil = 40℃±5℃) .
HLP46,Voil = 40℃±5℃) .
Spool symbola
Gubernator fluidi copia
1、4DWHG10
(1) Gubernator internus et gubernator externus: "P"portus cum M6 cochleae 3 gubernator externus est, ut valvae in gubernatorem internum convertant, M6 cochleae 3 amovendae sunt.
(2) Internum exhaurire et externum exhaurire: Removere fulmen 1, ut install M6 stupra 2 externum exhauriat, PRAETORQUEO M6 pressione 2 est internum exhaurire.
2、4DWHG16
(1) Gubernator internus et gubernator externus: Operculum laterale removere, paxillum inaugurari ut "P" portum cum positione aperta sit gubernator internus, ut clavum in "P" portum positis obturatis, externus exhauriat.
(2) Internum exhaurire et externum exhaurire: Removere fulmen 1 et inaugurari cochleae M6 2 externum exhaurire, PRAETORQUEO M6 stupra 2 est exhaurire internum.
Gubernator fluidi copia
3、4DWHG25
(1) Gubernator internus et gubernator externus: Removere operculum laterale, installare M6 cochleae 1 gubernator externus est, PRAETORQUEO M6 cochleae 2 gubernator internus est.
(2) Internum exhaurire et externum exhaurire: Removere M6 stupra 2 in "T" portum in vertice valvae principalis est exhaurire internum, inaugurari cochleae M6 2 externum exhaurire est.
4、4DWHG32
1、 Gubernator internus et gubernator externus: Installing M6 stupra 1 in "P" portum in vertice valvae principalis est gubernator externus removens cochleam M6 1 gubernator internus est.
2、 Internum exhaurire et externum exhaurire: Removere M6 cochlea 2 in "T" portum in summo valvae principalis est externum exhaurire;instruendo cochleae M6 2 internum exhaurire est.
NOTE : 1. "X" portus in lamina basi inplenda est si gubernator internus.
2. "Y" portum in lamina basi inplenda est si exhauriat internus.
4DWHG10 Subplate Installation Dimensiones
4DWHG16 Subplate Installation Dimensiones
Valvae scriptor set stupra
4 of M10×60 GB/T70.1-12.9 Constringens Aureus Ma=75Nm.
2 of M6×60 GB/T70.1-12.9 Aureus constringens Ma=15.5Nm.
O-anulum pro PTAB Portus: φ26×2.4
O-anulum pro XYL Portus: φ15×1.9
4DWHG22 Subplate Installation Dimensiones
Valvae scriptor set stupra
6 of M12×60 GB/T70.1-12.9 Aureus constringens Ma=130Nm.
O-anulum pro PTAB Portus: φ31×3.1
O-anulum pro XY Portus: φ25×3.1
4DWHG25 Subplate Installation Dimensiones
Valvae scriptor set stupra
6 of M12×60 GB/T70.1-12.9 Aureus constringens Ma=130Nm.
O-anulum pro PTAB Portus: φ34×3.1
O-anulum pro XY Portus: φ25×3.1
4DWHG32 Subplate Installation Dimensiones
Valvae scriptor set stupra
6 of M20×80 GB/T70.1-2000 12.9 Constringens Aureus Ma=430Nm.
O-anulum pro PTAB Portus: φ42×3
O-anulus XY Portus: φ19×3
installation dimensiones